DSP-VIP-5TL DSP-VIP-5-Series(5EM/5EL,5TM/5TL,5CM/5CL,5SM)
DSP-VIP-5-Series(5EM/5EL,5TM/5TL,5CM/5CL,5SM)
Main Feature
- Panel Mounting Type
- Access restricted to authorized operator : Password
- To response for various motor starting system and to use trip for the protection : the application for trip output according to Logic input
as follows : applied mode is "out/LooFF/a/b"
- Trip output : C1-M, 97-98/Main trip, 07-08/Aux
- As the control power is powered :
- for selecting LooFF(“Auto" is displayed in the initial state)
- disable for logic input
- C1-M:open⇢close in motor start/(open in trip)
- sequence for contactor ON-OFF ⇢ C1-M(b),97-98(a)/actually just like 1b-1a
- for selecting one of a / b("LOP", rcs. EFI are displayed in the initial state according to logic input state)
- C1-M:open ⇢ close in motor start
- sequence wiring for contator ON-OFF⇢C1-M(1b)
- Protection : Over current/Under current/Phase loss/Reverse phase/Locked rotor/Shock(Stall)/Ground fault,[Short circuit:5SM Type]
- Indication :Current(each phase line or average),earth current, load factor,accumulated working time[AWT]
- Current loop communication :4~20mA for max value of 3 phase current
- To cover a wide and precised current range for the protection
- 03 Type :0.2 ∼ 6A - only available for 5SM Type
- 70 Type : 0.2A∼70A --changed naturally into 0.2~6A with external CT if 5A is preset in cto mode or for 5SM type
- Extended current range with external CT : 1A∼3000A
- To keep a steady characteristics in the noisy installed environment : embedded RMS chip/correct RMS current value
- The classification for Logic Input :LOP>> rcs >> EFI(External Fault Input)/LOP:#1,#2, rCS:#4,#6:EFI
- To realize instant trip time for the ground fault protection :0.1∼30sec/Definite , 0.05sec/instant
- To realize instant trip time for the short circuit protection : 0.08 sec/instant T-I for 5SM Type
- "Shock" protection :availble for instant mechanical shock due to over load while crasher,roller,conveyer,etc are working
- To indicate a necessasary information in every 3 sec
- Convenient installation of ZCT to sense a zero phase current for GF protection
- Standard type : to use external ZCT(200mA/1.5mA)
- Optional type : embedded ZCT(not available for external CT application)
- High sensitive level and wide range for ground fault protection : 30mA ∼ 4A
- Main contactor auto close : in case a line power is "ON" again withinin a preset time(SDDT) after a line power is "OFF" during normal operation, main contactor is closed orderly according to another preset time(DOMT)
- Various way to reset after trip: Manual,Electrical or Automatic /to response flexibly for applied sequence system
- Self-diagonostic test by one touch for "CLR" key
- Alarm befor Tripping by over current
- History,Latest 8 trip events
- To have stable state under the noise environment :connection cable with line noise filter between indication meter and converter
- Convenient installation into existed meter hole:65Φ hole or rectangular hole
Easy Handling
- Current rating
- 70 Type : 0.2A∼70A / 0.5A~6A with external CT
- 03 Type : 0.2A ∼6A, Only for 5SM Type
- External CT : 1A ∼ 3000A
- Operation Time
- Starting trip delay time(dt) : 1 ~ 300sec /Definite T-I
- Over current trip delay time(ot)
- definite T-I:0.1~60sec
- Inverse :5~30 Class
- 0.08 sec/instant(5SM Type)
- Under current trip delay time : 0.1~30sec
- Phase loss trip delay time(PLc) : 1~5sec
- Reverse phase trip delay time : within 0.5sec
- Ground fault trip delay time : Edt/0.1~25sec,Eot/0.05,0.1~30sec
- current unbalance trip delay time : 8sec
- locked rotor trip delay time : dt+0.1sec
- Allowable tollerance
- Current : C≤2A : 0.2A, C>2A : ±5%
- Time : t≤2sec : ±0.2sec, t>2sec : ±10%
- Control power : 24VDC (Optional Type)
- Trip output
- Main : 97-98 : 1a(1-SPST),3A/Resistive
- C1-M : 1a (1-SPST),3A/Resistive
- Aux:07-08 : 1a(1-SPST),3A/Resistive(possible to output one of,AlEc/AL/uc/Shoc/Ec-ta/Ec-tb or SS(5SM type)
- Application environment
- Operation : -25℃ ~ +70℃
- Storage : -40℃ ~ +80℃
- Relative humidity : 30∼85%, non-condensing
- Stable operation under frequency variation from Inverter : 20Hz ∼ 400Hz ,avg ±5%
- Screw Torque : Max 0.6N.m
- Insulation Resistence / IEC-60255-5 : circuit-case, 10Mohm , 500VDC
- High Voltage Withstand Test : IEC-60255-5
- circuit-case : AC2000V, 60Hz, 1min
- contact-contact : AC1000V, 60Hz, 1min
- Lightning Impulse Voltage Withstand Test : IEC-60255-5
- Circuit-Ground, Circuit-Circuit : 1.2/50uS, 5KV
- Control Circuits : 1.2/50uS, 5KV
- 1MHz Burst Immunity Test / IEC 61000-4-18 : 2.5KV, Positive / Negative under 2sec
- Electrostatic Discharge : IEC-61000-4-2
- Air : Level 3, 8KV
- Contact : Level 13, 6KV
- Radiated Electromagnetic Field Disturbance / IEC-61000-4-3 : Level 3, 10V/m
- Electric Fast Transient Burst : IEC-61000-4-4
- power,relay output : Level 4, 4KV
- Surge Immunity test : IEC-61000-4-5
- relay output : 1.2×50uS, 2KV(0°, 90°, 180°, 270°)
- Conducted Disturbence Test / IEC-61000-4-6 : 10V, Level 3
- Control Voltage : AC 85V ∼ AC260V,50/60Hz (DC90V ∼ DC370V)
- Power consumption : 6W Max
Catalog
- CATEGORY
- SUBJECT
- DOWNLOAD
- MODIFY DATE
- Comprehensive Catalog
- 삼화디에스피 종합 카다로그
- 2310 삼화DSP 종합카다로그.pdf
- 2024-11-15
Cad
- CATEGORY
- SUBJECT
- DOWNLOAD
- MODIFY DATE
- DSP-5TL
- DSP-5TL.pdf
- 2020-11-18
- DWG
- DSP-5TL
- DSP-5TL.dwg
- 2020-11-18
Certification
Ordercode
Other Series
-
DSP-CTM-N
-
DSP-VIP-PM
-
DSP-VIP-PL
-
DSP-M200/M200-C/M200-VA
-
DSP-VIP-RTM
-
DSP-VIP-5SM
-
DSP-VIP-5CM
-
DSP-PCTM
-
DSP-PCM
-
DSP-CCTM
-
DSP-CCM-PT
-
DSP-AOM
-
DSP-AOM-N
-
DSP-AOL-RG
-
DSP-MWR-S
-
DSP-CM44
-
DSP-3CT
-
DSP-ZCT
-
WKS-1340SQH
-
DSP-UVR
-
DSP-VPR
-
DSP-SDTR-P:Socket-Pin Type
-
DSP-DVR
-
DSP-DCR
-
DSP-DGFR
-
DSP-POL-EC
-
DSP-UCR
-
DSP-3SD, 3SD-RG
-
WKS-3270HFAC
-
WKS-1210G2H04T
-
WKS-1220G2H04T
-
WKS-1230G2H04T
-
WKS-1240G2H04T
-
WKS-3340H04
-
WKS-1340G2H04T
-
WKS-1330G2H04T
-
WKS-1320G2H04T
-
WKS-0220MAB
-
WKS-3340HFAC
-
WKS-3340FRMN
-
WKS-3325FRMP
-
WKS-3340FRMP
-
WKS-1325MAC
-
WKS-3325FRMN
-
WKS-3325MAC
-
WKS-1325M04
-
WKS-3340MAC
-
WKS-1340MAC
-
WKS-3325M04
-
WKS-3370HFAC
-
WKS-3340M04
-
WKS-1340M04
-
WKS-3325H04
-
WKS-1370SQHAC
-
WKS-3340HAC
-
WKS-33130HF04T
-
WKS-3370HAC
-
WKS-3370HF04T
-
WKS-1370SQH
-
WKS-1225SQHAC
-
WKS-1240SQHAC
-
DSP-CM44E
-
WKS-1320G2HR
-
WKS-1320G2HA
-
WKS-1220G2HD
-
WKS-1220G2HR
-
DSP-AOM-RG
-
WKS-1203PBZL
-
WKS-0203PBZL
-
WKS-1320G2HD
-
WKS-1220G2HA
-
WKS-1350G2H04T
-
WKS-1310G2H04T
-
WKS-1250G2H04T
-
WKS-3240HFAC
-
WKS-3340HHAC
-
WKS-3325HHAC
-
WKS-3240HHAC
-
WKS-3225HHAC
-
WKS-33110HF04T
-
WKS-3340HF04T
-
WKS-3270HF04T
-
WKS-3240HF04T
-
WKS-3340HH04
-
WKS-3325HH04
-
WKS-3240HH04
-
WKS-3225HH04
-
WKS-3325HAC
-
WKS-3270HAC
-
WKS-3240HAC
-
WKS-3225HAC
-
WKS-3370H04
-
WKS-3270H04
-
WKS-3240H04
-
WKS-3225H04
-
WKS-1340SQHAC
-
WKS-1325SQHAC
-
WKS-1270SQHAC
-
DSP-IR
-
DSP-IRM
-
DSP-DGFR-M
-
DSP-DCR-M
-
DSP-DVR-M
-
DSP-VPFR
-
DSP-OVR
-
DSP-SP
-
DSP-2SD
-
DSP-AOL
-
DSP-CCM-N
-
DSP-CCL-PT
-
DSP-CCM-ET
-
DSP-CCM-E,CCM-ES
-
DSP-CSM
-
DSP-CSL
-
DSP-CCM
-
DSP-CCL
-
DSP-CTM
-
DSP-CTL
-
DSP-COM
-
DSP-COL
-
DSP-PCL
-
DSP-PTM
-
DSP-PTL
-
DSP-POM
-
DSP-POL
-
DSP-VIP-5CL
-
DSP-VIP-5TM
-
DSP-VIP-5TL
-
DSP-VIP-5EM
-
DSP-VIP-5EL
-
DSP-VIP-RTL
-
DSP-VIP-RM
-
DSP-VIP-RL
-
WKS-1325SQH
-
WKS-1270SQH
-
WKS-1240SQH
-
WKS-1225SQH
-
WKS-1370SQAC
-
WKS-1340SQAC
-
WKS-1325SQAC
-
WKS-1270SQAC
-
WKS-1240SQAC
-
WKS-1225SQAC
-
WKS-1370SQ
-
WKS-1340SQ
-
WKS-1325SQ
-
WKS-1270SQ
-
WKS-1240SQ
-
WKS-1225SQ
-
DSP-SSR Converter
-
DSP-E2CV
-
HJ-114SH
-
SW-ADS101
-
DSP-3SS
-
DSP-SS1
-
DSP-3SS-RG
-
DSP-SS1-AR
-
DSP-2CT
-
DSP-VIP-PRM
-
DSP-VIP-PRM